Texto completo
|
PDF (Portable Document Format)
- Acceso permitido solamente a usuarios en el campus de la UPM
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) |
ORCID: https://orcid.org/0000-0002-5286-5378, Prieto López, Roberto
ORCID: https://orcid.org/0000-0001-7361-6816, Cobos Márquez, José Antonio
ORCID: https://orcid.org/0000-0003-4542-2656, Huusari, J. and Suntio, T.
(2012).
Practical Characterization of Input-Parallel-Connected Converters with a Common Input Filter.
En: "Proceedings of the 27th IEEE Applied Power Electronics Conference and Exposition (APEC)", 05/02/2012 - 09/02/2012, Orlando (Florida, USA). pp. 1845-1852.
| Título: | Practical Characterization of Input-Parallel-Connected Converters with a Common Input Filter |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Ponencia en Congreso o Jornada (Artículo) |
| Título del Evento: | Proceedings of the 27th IEEE Applied Power Electronics Conference and Exposition (APEC) |
| Fechas del Evento: | 05/02/2012 - 09/02/2012 |
| Lugar del Evento: | Orlando (Florida, USA) |
| Título del Libro: | Applied Power Electronics Conference and Exposition (APEC), 2012 Twenty-Seventh Annual IEEE |
| Fecha: | Febrero 2012 |
| Materias: | |
| ODS: | |
| Escuela: | Centro de Electrónica Industrial (CEI) (UPM) |
| Departamento: | Otro |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
|
PDF (Portable Document Format)
- Acceso permitido solamente a usuarios en el campus de la UPM
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) |
The paper presents a method to analyze robust stability and transient performance of a distributed power system consisting of commercial converter modules interconnected through a common input filter. The method is based on the use of four transfer functions, which are measurable from the converter input and output terminals. It is shown that these parameters provide important information on the power module sensitivity to the interactions caused by the external impedances. Practical characterization for the described system structure is performed introducing special transfer functions utilized for the interactions assessment. Experimental results are provided to support the presented analysis procedure.
| ID de Registro: | 20871 |
|---|---|
| Identificador DC: | https://oa.upm.es/20871/ |
| Identificador OAI: | oai:oa.upm.es:20871 |
| URL Oficial: | http://ieeexplore.ieee.org/xpl/articleDetails.jsp?... |
| Depositado por: | Memoria Investigacion |
| Depositado el: | 13 Nov 2013 16:01 |
| Ultima Modificación: | 21 Feb 2024 13:23 |
Publicar en el Archivo Digital desde el Portal Científico