An analytical model for simulating the bond of prestressed concrete during the prestressed force release

Benitez Baena, Jose Maria ORCID: https://orcid.org/0000-0001-8305-0713 and Gálvez Ruiz, Jaime Carlos ORCID: https://orcid.org/0000-0001-9106-2917 (2012). An analytical model for simulating the bond of prestressed concrete during the prestressed force release. En: "IV International Symposium. Bond in Concrete 2012: Bond Anchorage Detailing", 17/06/2012 - 20/06/2012, Brescia, Italia. ISBN 978-88-907078-1-0. pp. 249-255.

Descripción

Título: An analytical model for simulating the bond of prestressed concrete during the prestressed force release
Autor/es:
Tipo de Documento: Ponencia en Congreso o Jornada (Artículo)
Título del Evento: IV International Symposium. Bond in Concrete 2012: Bond Anchorage Detailing
Fechas del Evento: 17/06/2012 - 20/06/2012
Lugar del Evento: Brescia, Italia
Título del Libro: Bond In Concrete 2012
Fecha: 17 Junio 2012
ISBN: 978-88-907078-1-0
Materias:
ODS:
Escuela: E.T.S.I. Aeronáuticos (UPM) [antigua denominación]
Departamento: Vehículos Aeroespaciales [hasta 2014]
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of INVE_MEM_2012_134726.pdf]
Vista Previa
PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (487kB) | Vista Previa

Resumen

A bond analytical model is proposed in this paper. The model is capable of reproducing the bond stress developed between the steel and concrete, in precast prestressed elements, during the entire process of prestressing force release. The bond stress developed in the transmission zone, where the bond stress is not constant, is also obtained. The steel and concrete stresses as well as the slip between both materials can be also estimated by means of the relation established in the model between these parameters and the bond stress. The model is validated with the results of a series of tests, considering different steel indentation depths and concrete covers and it is extended to evaluate the transmission length. This has been checked by comparing the transmission length predicted by the model and one measured experimentally in two series of tests.

Más información

ID de Registro: 22921
Identificador DC: https://oa.upm.es/22921/
Identificador OAI: oai:oa.upm.es:22921
URL Oficial: http://www.bondinconcrete2012.org/
Depositado por: Memoria Investigacion
Depositado el: 02 Abr 2014 16:24
Ultima Modificación: 20 Feb 2024 12:48