Texto completo
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (391kB) |
ORCID: https://orcid.org/0000-0002-1543-3066, Carpio Huertas, Jaime
ORCID: https://orcid.org/0000-0003-0239-283X, Juan Ruiz, Jesús
ORCID: https://orcid.org/0000-0003-2000-9013 and Alarcón Álvarez, Enrique
ORCID: https://orcid.org/0000-0001-6538-7814
(2011).
Operational Modal Analysis using Expectation Maximization Algorithm.
En: "8th International Conference on Structural Dynamics, EURODYN 2011", 04/07/2011 - 06/07/2011, Leuven (Bélgica). ISBN 978-90-760-1931-4.
| Título: | Operational Modal Analysis using Expectation Maximization Algorithm |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Ponencia en Congreso o Jornada (Artículo) |
| Título del Evento: | 8th International Conference on Structural Dynamics, EURODYN 2011 |
| Fechas del Evento: | 04/07/2011 - 06/07/2011 |
| Lugar del Evento: | Leuven (Bélgica) |
| Título del Libro: | Proceedings of the 8th International Conference on Structural Dynamics, EURODYN 2011 |
| Fecha: | 2011 |
| ISBN: | 978-90-760-1931-4 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | System identification in structures, State Space models, Kalman filter, Operational Modal analysis, Maximum likelihood estimation, Expectation Maximization algorithm |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Ingeniería de Organización, Administración de Empresas y Estadística |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (391kB) |
This paper presents a time-domain stochastic system identification method based on Maximum Likelihood Estimation and the Expectation Maximization algorithm. The effectiveness of this structural identification method is evaluated through numerical simulation in the context of the ASCE benchmark problem on structural health monitoring. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the benchmark structure have been estimated applying the proposed identification method to a set of 100 simulated cases. The numerical results show that the proposed method estimates all the modal parameters reasonably well in the presence of 30% measurement noise even. Finally, advantages and disadvantages of the method have been discussed.
| ID de Registro: | 26380 |
|---|---|
| Identificador DC: | https://oa.upm.es/26380/ |
| Identificador OAI: | oai:oa.upm.es:26380 |
| URL Oficial: | http://www.eurodyn2011.org/html/searchresults.html |
| Depositado por: | Biblioteca ETSI Industriales |
| Depositado el: | 22 May 2014 08:56 |
| Ultima Modificación: | 14 Feb 2023 08:52 |
Publicar en el Archivo Digital desde el Portal Científico