Distributed generation system with PEM fuel cell for electrical power quality improvement.
"International Journal of Hydrogen Energy", v. 33
(n. 16);
pp. 4433-4443.
ISSN 0360-3199.
https://doi.org/10.1016/j.ijhydene.2008.06.002.
| Título: | Distributed generation system with PEM fuel cell for electrical power quality improvement |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | International Journal of Hydrogen Energy |
| Fecha: | Agosto 2008 |
| ISSN: | 0360-3199 |
| Volumen: | 33 |
| Número: | 16 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | Distributed generation, power quality, fuel cell |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Ingeniería Eléctrica [hasta 2014] |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (482kB) | Vista Previa |
In this paper, a physical model for a distributed generation (DG) system with power quality improvement capability is presented. The generating system consists of a 5 kW PEM fuel cell, a natural gas reformer, hydrogen storage bottles and a bank of ultra-capacitors. Additional power quality functions are implemented with a vector-controlled electronic converter for regulating the injected power. The capabilities of the system were experimentally tested on a scaled electrical network. It is composed of different lines, built with linear inductances and resistances, and taking into account both linear and non-linear loads. The ability to improve power quality was tested by means of different voltage and frequency perturbations produced on the physical model electrical network.
| ID de Registro: | 2728 |
|---|---|
| Identificador DC: | https://oa.upm.es/2728/ |
| Identificador OAI: | oai:oa.upm.es:2728 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5483155 |