Deviations of cup anemometer rotational speed measurements due to steady state harmonic accelerations of the rotor

Martínez Muelas, Alejandro; Vega, Enrique; Pindado Carrion, Santiago; Meseguer, Encarnación y García, Luis (2016). Deviations of cup anemometer rotational speed measurements due to steady state harmonic accelerations of the rotor. "Measurement", v. 90 ; pp. 483-490. ISSN 0263-2241. https://doi.org/10.1016/j.measurement.2016.05.011.

Descripción

Título: Deviations of cup anemometer rotational speed measurements due to steady state harmonic accelerations of the rotor
Autor/es:
  • Martínez Muelas, Alejandro
  • Vega, Enrique
  • Pindado Carrion, Santiago
  • Meseguer, Encarnación
  • García, Luis
Tipo de Documento: Artículo
Título de Revista/Publicación: Measurement
Fecha: 2016
Volumen: 90
Materias:
Palabras Clave Informales: Cup anemometer; Wind speed measurements; Fourier analysis
Escuela: Instituto de Microgravedad Ignacio Da Riva (UPM)
Departamento: Sistemas Aeroespaciales, Transporte Aéreo y Aeropuertos
Grupo Investigación UPM: Desarrollo y Ensayos Aeroespaciales DEA
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) | Vista Previa

Resumen

The measurement deviations of cup anemometers are studied by analyzing the rotational speed of the rotor at steady state (constant wind speed). The differences of the measured rotational speed with respect to the averaged one based on complete turns of the rotor are produced by the harmonic terms of the rotational speed. Cup anemometer sampling periods include a certain number of complete turns of the rotor, plus one incomplete turn, the residuals from the harmonic terms integration within that incomplete turn (as part of the averaging process) being responsible for the mentioned deviations. The errors on the rotational speed due to the harmonic terms are studied analytically and then experimentally, with data from more than 500 calibrations performed on commercial anemometers.

Más información

ID de Registro: 40640
Identificador DC: http://oa.upm.es/40640/
Identificador OAI: oai:oa.upm.es:40640
Identificador DOI: 10.1016/j.measurement.2016.05.011
URL Oficial: http://www.sciencedirect.com/science/article/pii/S026322411630152X
Depositado por: Biblioteca ETSI Aeronauticos
Depositado el: 13 Jun 2016 10:03
Ultima Modificación: 28 Jul 2016 09:53
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM