Improved high-speed de-excitation system for brushless synchronous machines tested on a 20 MVA hydro-generator.
"IET Electric Power Applications", v. 9
(n. 6);
pp. 405-411.
ISSN 1751-8660.
https://doi.org/10.1049/iet-epa.2014.0313.
| Título: | Improved high-speed de-excitation system for brushless synchronous machines tested on a 20 MVA hydro-generator |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | IET Electric Power Applications |
| Fecha: | 16 Abril 2015 |
| ISSN: | 1751-8660 |
| Volumen: | 9 |
| Número: | 6 |
| Materias: | |
| ODS: | |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Ingeniería Eléctrica [hasta 2014] |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) | Vista Previa |
Synchronous machines with brushless excitation have the disadvantage that the field winding is not accessible for the de-excitation of the machine. This means that, despite the proper operation of the protection system, the slow de-excitation time constant may produce severe damage in the event of an internal short circuit. A high-speed de-excitation system for these machines was developed, and this study presents the continuation of a previously published study. This study presents the design by computer simulation and the results of the first commissioning of this de-excitation system in a commercial 20 MVA hydro-generator. The de-excitation is achieved by inserting resistance in the field circuit, obtaining a dynamic response similar to that achieved in machines with static excitation. In this case, a non-linear discharge resistor was used, making the dynamic response even better.
| ID de Registro: | 40758 |
|---|---|
| Identificador DC: | https://oa.upm.es/40758/ |
| Identificador OAI: | oai:oa.upm.es:40758 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5491913 |