Direct comparison of the sensitivity of QCMs and AlN-based TFRs biosensors

Escolano Moyano, José Miguel, Díaz Durán, Bárbara, Olivares Roza, Jimena ORCID: https://orcid.org/0000-0003-4396-4363, Clement Lorenzo, Marta ORCID: https://orcid.org/0000-0003-4956-8206, Mirea, Teona ORCID: https://orcid.org/0000-0003-2324-4895 and Iborra Grau, Enrique ORCID: https://orcid.org/0000-0002-1385-1379 (2016). Direct comparison of the sensitivity of QCMs and AlN-based TFRs biosensors. "Proceedings of the 30th anniversary eurosensors conference - EUROSENSORS 2016", v. 168 ; pp. 481-484. ISSN 1877-7058. https://doi.org/10.1016/j.proeng.2016.11.136.

Descripción

Título: Direct comparison of the sensitivity of QCMs and AlN-based TFRs biosensors
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Proceedings of the 30th anniversary eurosensors conference - EUROSENSORS 2016
Fecha: Septiembre 2016
ISSN: 1877-7058
Volumen: 168
Materias:
ODS:
Palabras Clave Informales: Biosensor; quartz crystal microbalance; thin film resonators; AlN
Escuela: E.T.S.I. Telecomunicación (UPM)
Departamento: Ingeniería Electrónica
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of INVE_MEM_2016_248440.pdf]
Vista Previa
PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (157kB) | Vista Previa

Resumen

We present the direct comparison of the performance of two gravimetric biosensors based on acoustic resonators, a quartz crystal microbalance and a high frequency AlN-based bulk acoustic wave film solidly mounted resonator (SMR). Both sensors are functionalized with streptavidin to detect the response to TBA29 aptamer biotin modified and different concentrations of thrombin. Experimental results reveal that both sensors succeed in detecting the targeted species, although SMRs show significantly greater sensitivity and a lower limit of detection

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
FP7
304814
RAPTADIAG
Sin especificar
Rapid Aptamer based diagnostics for bacterial meningitis
Gobierno de España
MAT2013-45957-R
Sin especificar
Sin especificar
Materiales avanzados para biosensores basados en resonadores piezoeléctricos combinados con nanotubos de carbono y grafeno

Más información

ID de Registro: 46143
Identificador DC: https://oa.upm.es/46143/
Identificador OAI: oai:oa.upm.es:46143
Identificador DOI: 10.1016/j.proeng.2016.11.136
URL Oficial: https://doi.org/10.1016/j.proeng.2016.11.136
Depositado por: Memoria Investigacion
Depositado el: 03 Jun 2017 08:43
Ultima Modificación: 21 Mar 2019 15:29