Developing optical label-free Point-of-Care biosensing devices

Maigler López, Mª Victoria; Holgado Bolaños, Miguel; Lavín Hueros, Álvaro; Vicente, Manuel; Domingo, Martín; Sanza Gutiérrez, Francisco Javier; Laguna Heras, Maria Fe; Santamaría, B.; López Espinosa, Rocío y López Romero, David (2017). Developing optical label-free Point-of-Care biosensing devices. En: "Industriales Research Meeting 2017", 4 y 5 de abril de 2017, Madrid, España. ISBN 978-84-16397-58-7. p. 45.

Descripción

Título: Developing optical label-free Point-of-Care biosensing devices
Autor/es:
  • Maigler López, Mª Victoria
  • Holgado Bolaños, Miguel
  • Lavín Hueros, Álvaro
  • Vicente, Manuel
  • Domingo, Martín
  • Sanza Gutiérrez, Francisco Javier
  • Laguna Heras, Maria Fe
  • Santamaría, B.
  • López Espinosa, Rocío
  • López Romero, David
Tipo de Documento: Ponencia en Congreso o Jornada (Póster)
Título del Evento: Industriales Research Meeting 2017
Fechas del Evento: 4 y 5 de abril de 2017
Lugar del Evento: Madrid, España
Título del Libro: Industriales Research Meeting 2017
Fecha: 2017
ISBN: 978-84-16397-58-7
Materias:
Escuela: E.T.S.I. Industriales (UPM)
Departamento: Física Aplicada e Ingeniería de Materiales
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (941kB) | Vista Previa

Resumen

The aim of this work is to develop a compact point-of-care device as a proof of concept of a novel read-out methodology than enhances the biosensing response by improving significantly the LoD and makes the interrogation process simple and more reliable. The measured signal is called Increase Relative Optical Power (IROP) and is a function of the optical power or irradiance for a certain optical interrogation band of two interferometers (reference and signal). The functionality of this device is validated by performing standard immunoassays and comparing these results with high resolution spectrometry.

Más información

ID de Registro: 50340
Identificador DC: http://oa.upm.es/50340/
Identificador OAI: oai:oa.upm.es:50340
URL Oficial: http://www.etsii.upm.es/investigacion/irm17/index.es.htm
Depositado por: Memoria Investigacion
Depositado el: 17 Jul 2018 15:57
Ultima Modificación: 17 Jul 2018 15:57
  • GEO_UP4
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • InvestigaM
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM