A new pump selection method for large-power PV irrigation systems at a variable frequency

Hogan Teves de Almeida, Rita, Ramirez Ledesma, Francisco Javier, Barata Carrelo, Isaac Afonso, Narvarte Fernández, Luis ORCID: https://orcid.org/0000-0002-6289-7605, Ferrara, G. and Antipodi, L. (2018). A new pump selection method for large-power PV irrigation systems at a variable frequency. "Energy Conversion and Management", v. 174 ; pp. 874-885. ISSN 0196-8904. https://doi.org/10.1016/j.enconman.2018.08.071.

Descripción

Título: A new pump selection method for large-power PV irrigation systems at a variable frequency
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Energy Conversion and Management
Fecha: Octubre 2018
ISSN: 0196-8904
Volumen: 174
Materias:
ODS:
Palabras Clave Informales: Photovoltaic, PV irrigation systems, Pump selection method, Variable frequency, Water pumping
Escuela: E.T.S.I. y Sistemas de Telecomunicación (UPM)
Departamento: Otro
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of INVE_MEM_2018_281641.pdf]
Vista Previa
PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (4MB) | Vista Previa

Resumen

This paper presents a new method for selecting a pump for large-power PV irrigation systems working at a variable frequency. This can have a significant impact since the traditional way of selecting the pump is based on maximizing the efficiency of pump in the duty point at a certain single operating frequency, which is not useful for PV irrigation systems working at a variable frequency. The proposed method starts by considering the pumps with H-Q curves with a high slope and the duty point in the right-hand third of the curve to assure a wide range of operating frequencies. Then, the efficiency within the whole range of frequencies is evaluated. An example of a performance comparison between the pumps selected with the new and traditional methods has been carried out. Results show that by using the new method, the yearly volume of water pumped increases by 7.2-21.0% and the pump efficiency by 4.3-5.3%. Finally, it is important to mention that the proposed method has already been implemented in the SISIFO tool, able to simulate PV irrigation systems.

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
Horizonte 2020
640771
MASLOWATEN
UNIVERSIDAD POLITÉCNICA DE MADRID
MArket uptake of an innovative irrigation Solution based on LOW WATer-ENergy consumption

Más información

ID de Registro: 52284
Identificador DC: https://oa.upm.es/52284/
Identificador OAI: oai:oa.upm.es:52284
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/5497737
Identificador DOI: 10.1016/j.enconman.2018.08.071
URL Oficial: https://www.sciencedirect.com/science/article/pii/...
Depositado por: Dr. Luis Narvarte Fernández
Depositado el: 17 Sep 2018 10:50
Ultima Modificación: 12 Nov 2025 00:00