Texto completo
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (2MB) | Vista Previa |
ORCID: https://orcid.org/0000-0001-9299-1371, Laguna Heras, Maria Fe
ORCID: https://orcid.org/0000-0002-1580-4509, Sanza Gutiérrez, Francisco Javier, Santamaría Fernández, Beatriz
ORCID: https://orcid.org/0000-0003-3714-7922, Lavín Hueros, Álvaro
ORCID: https://orcid.org/0000-0001-9981-2372 and López Espinosa, Rocío
ORCID: https://orcid.org/0000-0001-8524-7229
(2018).
A New Device Based on Interferometric Optical Detection Method for Label-Free Screening of C-Reactive Protein.
"IEEE Transactions on Instrumentation and Measurement"
;
pp. 1-7.
ISSN 1557-9662.
https://doi.org/10.1109/TIM.2018.2876073.
| Título: | A New Device Based on Interferometric Optical Detection Method for Label-Free Screening of C-Reactive Protein |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | IEEE Transactions on Instrumentation and Measurement |
| Fecha: | 2018 |
| ISSN: | 1557-9662 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | C-reactive protein (CRP); label-free optical biosensors; point-of-care (PoC) devices; screening of immunoassays |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Otro |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (2MB) | Vista Previa |
In previous work, the performance of a compact and cost-effective point-of-care (PoC) device based on the increase relative optical power (IROP) methodology is reported and it is determined the enhancement in comparison with standard high-resolution spectrometry in terms of limit of detection. This paper describes a new label-free IROP-based biomedical device capable of working with low concentration of reagents and low sample volume per measurement in order to be used for screening different steps necessary in immunoassay optimization. This new approach significantly improves the sensing performance in terms of read-out signal (AIROP) per nanometer of biofilm in comparison with our previous work. This improvement is achieved due to the implementation of a laser as light source of the optical read-out system and the redesign of Fabry-Perot transducers by optimizing their reflectivity response and reducing their sensing area. For demonstrating the screening capability of this new PoC device in several immunoassays steps and methodologies, a C-reactive protein detection assay was carried out as a potential application and assay model. It is remarkable that only 10 μL of sample was used per measurement. This labelfree IROP-based device complies an easy-to-use and cost-effective tool for immunoassays optimization in terms of performance, reagents cost, and measuring time.
| ID de Registro: | 54829 |
|---|---|
| Identificador DC: | https://oa.upm.es/54829/ |
| Identificador OAI: | oai:oa.upm.es:54829 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5657939 |
| Identificador DOI: | 10.1109/TIM.2018.2876073 |
| Depositado por: | Memoria Investigacion |
| Depositado el: | 09 May 2019 15:08 |
| Ultima Modificación: | 12 Nov 2025 00:00 |
Publicar en el Archivo Digital desde el Portal Científico