Texto completo
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (7MB) |
ORCID: https://orcid.org/0000-0002-2192-3053, Rescalvo, Francisco
ORCID: https://orcid.org/0000-0002-9211-1634, Donaire Ávila, Jesús
ORCID: https://orcid.org/0000-0003-4764-1852, Galé Lamuela, David
ORCID: https://orcid.org/0000-0002-3110-0050, Benavent Climent, Amadeo
ORCID: https://orcid.org/0000-0002-9406-6726 and Gallego Molina, Antolino
ORCID: https://orcid.org/0000-0001-5279-9094
(2019).
Temporal acoustic emission index for damage monitoring of RC structures subjected to bidirectional seismic loadings.
"Materials", v. 12
(n. 7);
p. 2804.
ISSN 1996-1944.
https://doi.org/10.3390/ma12172804.
| Título: | Temporal acoustic emission index for damage monitoring of RC structures subjected to bidirectional seismic loadings |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Materials |
| Fecha: | 30 Agosto 2019 |
| ISSN: | 1996-1944 |
| Volumen: | 12 |
| Número: | 7 |
| Materias: | |
| Palabras Clave Informales: | Acoustic emission; concrete structure; Damage; seismic loadings; b-value; Classification; Mode; Performance; Reinforced-Concrete Slabs; Signal Processing; Tests |
| Escuela: | E.T.S.I. Industriales (UPM) |
| Departamento: | Ingeniería Mecánica |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (7MB) |
This paper shows the acoustic emission (AE) analysis recorded during the loading process of reinforced concrete (RC) structures subjected to bidirectional seismic loadings. Two waffle plates (bidirectional) supported by isolated square columns were tested on a shaking table with a progressive and increasing ground acceleration until the final collapse. Each specimen was subjected to a different loading history. A relevant delay in the beginning of the significant AE energy is observed as the peak value of the ground acceleration increases. Based on this result, a new AE temporal damage index (TDI), defined as the time difference between the onset of the significant AE activity and the onset of the loading that causes this AE activity, is proposed and validated by comparing it with the plastic strain energy released by the concrete, typically used as a reliable damage level indicator. Good agreement was observed for both specimens and seismic inputs.
| ID de Registro: | 86002 |
|---|---|
| Identificador DC: | https://oa.upm.es/86002/ |
| Identificador OAI: | oai:oa.upm.es:86002 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5825655 |
| Identificador DOI: | 10.3390/ma12172804 |
| URL Oficial: | https://www.mdpi.com/1996-1944/12/17/2804 |
| Depositado por: | iMarina Portal Científico |
| Depositado el: | 14 Ene 2025 10:19 |
| Ultima Modificación: | 14 Ene 2025 10:19 |
Publicar en el Archivo Digital desde el Portal Científico