A global analysis of a coupled violent vertical sloshing problem using an SPH methodology

Calderón Sánchez, Javier ORCID: https://orcid.org/0000-0003-0636-8853, Martínez Carrascal, Jon ORCID: https://orcid.org/0000-0003-1110-6700, González Gutiérrez, Leo Miguel ORCID: https://orcid.org/0000-0002-1629-0001 and Colagrossi, Andrea ORCID: https://orcid.org/0000-0001-7123-3272 (2021). A global analysis of a coupled violent vertical sloshing problem using an SPH methodology. "Engineering Applications of Computational Fluid Mechanics", v. 15 (n. 1); pp. 865-888. ISSN 19942060. https://doi.org/10.1080/19942060.2021.1921849.

Descripción

Título: A global analysis of a coupled violent vertical sloshing problem using an SPH methodology
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Engineering Applications of Computational Fluid Mechanics
Fecha: 1 Enero 2021
ISSN: 19942060
Volumen: 15
Número: 1
Materias:
Palabras Clave Informales: Delta-Plus-Sph; Energy-Dissipation; Free-Surface Flows; Liquid; Model; Motions; Rolling Rectangular Tank; Simulation; Sloshing; Smoothed Particle Hydrodynamics; Viscosity; Waves
Escuela: E.T.S.I. Navales (UPM)
Departamento: Arquitectura, Construcción y Sistemas Oceánicos y Navales (Dacson)
Licencias Creative Commons: Reconocimiento

Texto completo

[thumbnail of 87567.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (4MB)

Resumen

A dynamical system involving the decaying test of a partially filled liquid tank is analyzed in the present paper. This analysis is relevant for the design of aircraft fuel tanks, where the wings' structural dynamics are influenced by the complexity and the violence of the internal flow generated when atmospheric turbulence or gust is encountered. The study of this kind of system is performed in order to understand the extra energy dissipation caused by the confined fluid, and the interacting force between the fluid and the tank resulting from the vertical sloshing. A complete non-dimensional analysis of the problem in terms of additional damping has been performed, and the dependency on the most relevant non-dimensional numbers has been monitored. A coupled numerical simulation where both the tank and the fluid are combined has been used to study the system, and their results are compared to previous experiments. A smoothed particle hydrodynamics model, extensively validated in the sloshing literature, is used to calculate the magnitude and frequency of the vertical force between the fluid and the tank. The extra dissipation of the tank's mechanical energy caused by the fluid action is quantified for a particular configuration with constant filling level and a wide range of non-dimensional numbers. The sensitivity of the extra damping to the variation of the non-dimensional numbers is evaluated, and the most relevant ones are compared to the equivalent experimental tests. Results show that the numerical tool developed is able to capture the different phenomena involved and can be used to determine the influence of the different phenomena happening in violent vertically excited flows.

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
Horizonte 2020
815044
Sin especificar
Sin especificar
Sin especificar

Más información

ID de Registro: 87567
Identificador DC: https://oa.upm.es/87567/
Identificador OAI: oai:oa.upm.es:87567
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/9336903
Identificador DOI: 10.1080/19942060.2021.1921849
URL Oficial: https://www.tandfonline.com/doi/full/10.1080/19942...
Depositado por: iMarina Portal Científico
Depositado el: 31 Ene 2025 18:28
Ultima Modificación: 31 Ene 2025 18:28