Modelo de análisis integral de factibilidad de utilización de Thermo Active Building Systems en edificios de oficinas = Comprehensive model for the analysis of feasibility of the use of Thermoactive Building Systems in office buildings in Chile

Gálvez Huerta, Miguel Ángel ORCID: https://orcid.org/0000-0002-9272-4019, Barraza Vicencio, Rodrigo ORCID: https://orcid.org/0000-0002-6737-9145, Hormazábal Poblete, Nina ORCID: https://orcid.org/0000-0002-7607-7675, Curinao, Álvaro and Gil López, Tomás ORCID: https://orcid.org/0000-0003-3819-8756 (2020). Modelo de análisis integral de factibilidad de utilización de Thermo Active Building Systems en edificios de oficinas = Comprehensive model for the analysis of feasibility of the use of Thermoactive Building Systems in office buildings in Chile. "Dyna", v. 95 (n. 3); pp. 317-321. ISSN 00127361. https://doi.org/10.6036/9575.

Descripción

Título: Modelo de análisis integral de factibilidad de utilización de Thermo Active Building Systems en edificios de oficinas = Comprehensive model for the analysis of feasibility of the use of Thermoactive Building Systems in office buildings in Chile
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Dyna
Fecha: 1 Junio 2020
ISSN: 00127361
Volumen: 95
Número: 3
Materias:
Palabras Clave Informales: comfort; Energy; Envelope; Envelope Thermal comfort; OFFICE BUILDINGS; Performance; TABS; Thermal comfort; thermal simulation
Escuela: E.T.S. de Edificación (UPM)
Departamento: Tecnología de la Edificación
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of 6300967.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB)

Resumen

© 2020 Publicaciones Dyna Sl. All rights reserved. The work addresses the construction of a simplified computational model to evaluate the feasibility of the use of Thermo Active Buildings Systems (TABS) for office buildings in Chile, in order to set the theoretical basis for the design and dimensioning of these systems in the Chilean context, taking into account specific local conditions like its high seismic risk and the extreme variation of climates. To do so, an analytic model has been conceived, using the Engineering Equation Solver (EES) software. Firstly, a simple base model for a typical office building has been developed, and has been next applied to the climate conditions of eight climatic zones, ranging from the Atacama Desert to the Patagonia region. The results show a quite different performance of the system depending of the ambient conditions. They also reveal relevant aspects to be considered when designing TABS, such as the control strategies. The information obtained with the model will eventually serve as a base line to choose the appropriate set of design strategies for each climatic zone.

Más información

ID de Registro: 91593
Identificador DC: https://oa.upm.es/91593/
Identificador OAI: oai:oa.upm.es:91593
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/6300967
Identificador DOI: 10.6036/9575
URL Oficial: https://www.revistadyna.com/search/comprehensive-m...
Depositado por: iMarina Portal Científico
Depositado el: 24 Oct 2025 06:10
Ultima Modificación: 24 Oct 2025 06:10