Electrochemical Study of Clean and Pre-Corroded Reinforcements Embedded in Mortar Samples with Variable Amounts of Chloride Ions

González García, María de las Nieves ORCID: https://orcid.org/0000-0002-0299-0840, Prieto Barrio, María Isabel ORCID: https://orcid.org/0000-0003-2797-3964, Cobo Escamilla, Alfonso ORCID: https://orcid.org/0000-0001-8270-7752 and Olmedo Zazo, Fernando Israel ORCID: https://orcid.org/0000-0002-3400-817X (2021). Electrochemical Study of Clean and Pre-Corroded Reinforcements Embedded in Mortar Samples with Variable Amounts of Chloride Ions. "Materials", v. 14 (n. 22); p. 6883. ISSN 1996-1944. https://doi.org/10.3390/ma14226883.

Descripción

Título: Electrochemical Study of Clean and Pre-Corroded Reinforcements Embedded in Mortar Samples with Variable Amounts of Chloride Ions
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Materials
Fecha: 1 Noviembre 2021
ISSN: 1996-1944
Volumen: 14
Número: 22
Materias:
ODS:
Palabras Clave Informales: Armaduras ; Corrosión ; Acero ; Iones de cloro ; Técnicas electroquímicas
Escuela: E.T.S. de Edificación (UPM)
Departamento: Construcciones Arquitectónicas y su Control
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of 9891192.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (5MB)

Resumen

The present study investigates the possibility of re-surfacing previously corroded reinforcements and the suitability of the two electrochemical techniques that are widely used to determine the state of corrosion of steel (the corrosion potential Ecorr and the corrosion rate icorr). In order to test this, 32 pre-corroded B500SD reinforcing steel bars have been used for one year, where half of the bars have been cleaned to eliminate corrosion products. The other half have been maintained with the generated corrosion products. Subsequently, the bars have been embedded in cement mortar samples with variable amounts of chloride ion, and Ecorr and icorr have been measured for 250 days. The results showed that it is not possible to rework the reinforcement without removing corrosion products and that it is not possible to predict the passive or active state of steel by measuring Ecorr only.

Más información

ID de Registro: 93314
Identificador DC: https://oa.upm.es/93314/
Identificador OAI: oai:oa.upm.es:93314
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/9891192
Identificador DOI: 10.3390/ma14226883
URL Oficial: https://www.mdpi.com/1996-1944/14/22/6883
Depositado por: iMarina Portal Científico
Depositado el: 23 Ene 2026 20:08
Ultima Modificación: 18 Mar 2026 20:06