Structural deterioration and failure of the laminated wooden roof of a covered swimming pool

Pinilla Melo, Javier ORCID: https://orcid.org/0000-0002-9390-2083, Flores Medina, Nelson, Sánchez Aparicio, Luis Javier ORCID: https://orcid.org/0000-0001-6758-2234 and Aira Zunzunegui, José Ramón ORCID: https://orcid.org/0000-0002-4598-5259 (2024). Structural deterioration and failure of the laminated wooden roof of a covered swimming pool. "Buildings", v. 14 (n. 12); p. 3794. ISSN 2075-5309. https://doi.org/10.3390/buildings14123794.

Descripción

Título: Structural deterioration and failure of the laminated wooden roof of a covered swimming pool
Autor/es:
Tipo de Documento: Artículo
Título de Revista/Publicación: Buildings
Fecha: 27 Noviembre 2024
ISSN: 2075-5309
Volumen: 14
Número: 12
Materias:
ODS:
Palabras Clave Informales: Corrosion; Damage diagnosis; Glulam; heated swimming pool; heated swimming pool; Non-destructive testing; Structural failure; wet rot
Escuela: E.T.S. Arquitectura (UPM)
Departamento: Construcción y Tecnología Arquitectónica
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[thumbnail of 10309411.pdf] PDF (Portable Document Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (9MB)

Resumen

A swimming pool in Corrales de Buelna (Cantabria) was demolished in March 2017 due to the loss of mechanical performance of the laminated timber structure. The relevant deterioration was caused by rotting of the wood and corrosion of the metal connecting elements. The structure featured a barrel vault with five large tri-articulated arches enclosed on the sides by inclined facades formed by toral rafters and purlins. The corresponding diagnostic process involved data collection and structural assessments to verify the structure's bearing capacity and serviceability. Data collection was carried out in December 2015 and consisted of a thermal camera inspection to determine the points of moisture accumulation and sampling openings, conduct environmental and wood hygrothermal measurements, and measure cross-sectional losses and deformations of the structural elements. Verification of the load-bearing capacity was carried out using matrix calculation structure software for both the original and deteriorated structure. The diagnosis indicated that the damage was caused by leaks in the joints of the aluminum composite roof panels and by the insufficient load-bearing capacity of the structure. The severity of the damage compromised the mechanical strength and stability of the building, leading to a recommendation that the use of the facilities be immediately discontinued. The degree of deterioration left the structure unrecoverable, making it very difficult to apply reinforcement measures. These factors led to the structure's demolition to prevent its collapse.

Proyectos asociados

Tipo
Código
Acrónimo
Responsable
Título
Comunidad de Madrid
APOYO-JOVENES-21- RCDT1L-85- SL9E1R
CAREEN
Sin especificar
Desarrollo de nuevos métodos basados en inteligenCia ARtificial para la caracterización de daños en cosntruccioEs históricas a través de nubEs de puNtos 3D

Más información

ID de Registro: 89013
Identificador DC: https://oa.upm.es/89013/
Identificador OAI: oai:oa.upm.es:89013
URL Portal Científico: https://portalcientifico.upm.es/es/ipublic/item/10309411
Identificador DOI: 10.3390/buildings14123794
URL Oficial: https://www.mdpi.com/2075-5309/14/12/3794
Depositado por: iMarina Portal Científico
Depositado el: 09 May 2025 07:33
Ultima Modificación: 09 May 2025 07:33