Texto completo
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (3MB) |
ORCID: https://orcid.org/0000-0002-8720-3593, Barbero Barrera, María del Mar
ORCID: https://orcid.org/0000-0002-4605-3154, Cañas Guerrero, Ignacio
ORCID: https://orcid.org/0000-0002-6337-6377, Ramos Sanz, Alba
ORCID: https://orcid.org/0000-0003-4069-4740, Baptista, Fátima and Ruiz Mazarrón, Fernando
ORCID: https://orcid.org/0000-0002-6653-6911
(2024).
Construction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilities.
"Buildings", v. 14
(n. 3);
ISSN 2075-5309.
https://doi.org/10.3390/buildings14030655.
| Título: | Construction Solutions, Cost and Thermal Behavior of Efficiently Designed Above-Ground Wine-Aging Facilities |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Buildings |
| Fecha: | 1 Marzo 2024 |
| ISSN: | 2075-5309 |
| Volumen: | 14 |
| Número: | 3 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | wine; aging; above-ground warehouse; construction; cost; damping |
| Escuela: | E.T.S. de Ingeniería Agronómica, Alimentaria y de Biosistemas (UPM) |
| Departamento: | Ingeniería Agroforestal |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (3MB) |
The wine industry requires a considerable amount of energy, with an important fraction corresponding to the cooling and ventilation of above-ground aging warehouses. The large investments made in aging facilities can compromise the viability and competitiveness of wineries if their design is not optimized. The objective of this study was to provide guidance for the efficient design of new above-ground warehouses. To this end, multiple construction solutions (structure, envelopes, levels of integration, etc.) were characterized, and their costs and the resulting interior environments were analyzed. The results offer a comprehensive view of potential construction solutions and benchmark price ranges for viable and profitable designs. With a total cost of 300 EUR/m2, an average damping of 98% per day can be achieved. Increasing the costs does not imply better effectiveness. A double enclosure with internal insulation—with or without an air chamber—can achieve excellent results. Greater integration as a result of several enclosures being in contact with other rooms and/or the terrain allows for a high effectiveness to be achieved without air conditioning. Perimeter glazing and ventilation holes can reduce the effectiveness of the construction, resulting in greater instability and a lower damping capacity.
| ID de Registro: | 90705 |
|---|---|
| Identificador DC: | https://oa.upm.es/90705/ |
| Identificador OAI: | oai:oa.upm.es:90705 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/10206490 |
| Identificador DOI: | 10.3390/buildings14030655 |
| URL Oficial: | https://www.mdpi.com/2075-5309/14/3/655 |
| Depositado por: | iMarina Portal Científico |
| Depositado el: | 11 Sep 2025 13:04 |
| Ultima Modificación: | 06 Mar 2026 11:44 |
Publicar en el Archivo Digital desde el Portal Científico