Curvelets for Contact-less Hand Biometrics under varied environmental conditions.
"2017 International Carnahan Conference On Security Technology (ICCST)"
;
pp..
ISSN 1071-6572.
https://doi.org/10.1109/CCST.2017.8167805.
| Título: | Curvelets for Contact-less Hand Biometrics under varied environmental conditions |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | 2017 International Carnahan Conference On Security Technology (ICCST) |
| Fecha: | 2017 |
| ISSN: | 1071-6572 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | Contactless; Curvelets; Hand Biometrics; Hand Geometry; Palmprint; Multimodal Biometrics; Varied Environmental Conditions |
| Escuela: | Centro de Domótica Integral (CeDInt) (UPM) |
| Departamento: | Otro |
| Licencias Creative Commons: | Reconocimiento - Sin obra derivada - No comercial |
Vista Previa |
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (179kB) | Vista Previa |
In this work, the Curvelet transform is proposed as a fairly new feature extraction method for palmprint recognition. Particularly, a multiscale analysis has been performed at four levels, assessing and combining the features extracted at each level in order to find those which better represent the palmprint. Feature matching has been conducted by means of Euclidean distance and Support Vector Machines (SVMs), and comparative results are provided. In addition, a multimodal approach involving the extracted palmprint features and hand geometry features has also been evaluated, obtaining an improvement of the results in relation to monomodal biometrics. Evaluations have been carried out following an evaluation protocol based on the definitions suggested by the ISO/IDE 19795 norm that allows for a fair comparison between the different methods. To this end, images coming from two different contact-less databases, which cover different capturing conditions, have been employed.
| ID de Registro: | 50836 |
|---|---|
| Identificador DC: | https://oa.upm.es/50836/ |
| Identificador OAI: | oai:oa.upm.es:50836 |
| Identificador DOI: | 10.1109/CCST.2017.8167805 |
| URL Oficial: | https://ieeexplore.ieee.org/document/8167805 |
| Depositado por: | Memoria Investigacion |
| Depositado el: | 25 Nov 2022 15:13 |
| Ultima Modificación: | 09 Feb 2024 12:34 |
Publicar en el Archivo Digital desde el Portal Científico