Calculation methods of Radon-222 radiological activity for NORM plant with ventilation.
"Journal of Petroleum Science and Engineering", v. 183
(n. 106360);
ISSN 09204105.
https://doi.org/10.1016/j.petrol.2019.106360.
| Título: | Calculation methods of Radon-222 radiological activity for NORM plant with ventilation |
|---|---|
| Autor/es: |
|
| Tipo de Documento: | Artículo |
| Título de Revista/Publicación: | Journal of Petroleum Science and Engineering |
| Fecha: | 1 Diciembre 2019 |
| ISSN: | 09204105 |
| Volumen: | 183 |
| Número: | 106360 |
| Materias: | |
| ODS: | |
| Palabras Clave Informales: | building-materials; delay chamber; emanation; entry; houses; isotope; mitigation; natural radiation-exposure; oil; radioactive pollution; radioactivity; radon exhalation; radon gas; thoron; waste disposal |
| Escuela: | E.T.S. de Edificación (UPM) |
| Departamento: | Tecnología de la Edificación |
| Licencias Creative Commons: | Ninguna |
|
PDF (Portable Document Format)
- Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (1MB) |
© 2019 Elsevier B.V. A procedure is proposed to determine the radiological activity of air present in the working area of a NORM (Naturally-Occurring Radioactive Materials) plant. This NORM plant is located in the United Arab Emirates and is dedicated to the recycling of material and equipment used in oil extraction facilities. Substantial quantities of NORM waste will be present inside the enclosed plant facilities and will exhale significant amounts of Radon-222 into the working environment. The continued inhalation of this gas and its progeny has been shown to cause lung cancer. In order to reduce the concentration level of the aforementioned gas to an acceptable regulatory value, the best solution is by means of mechanical ventilation. The two calculation methods used to analysis the relationship between the ventilation rate and the degree of radioactive contamination are considered. The first being ventilation by perfect dilution, commonly employed in industrial environments with radiological contamination. The second method of analysis is by means of a CFD (Computational Fluid Dynamics) which permits a more precise calculation of the required fresh air quantity and spatial concentrations. Validation was carried out in a small experimental plant space, obtaining results reasonable approximate to those predicted by the computational analysis. The similarities and differences between the respective calculation methods and their respective fields of application are analyzed. It is concluded that for lower air change rates, less than five air changes per hour, the CFD analysis is the most appropriate method. By contrast, when using a higher rate of outside air changes in the plant, the perfect dilution method should be sufficient enough to control the presence of radon and its progeny. Both calculation methods consider the activity of radon and the activity of the most significant radioisotopes of its progeny.
| ID de Registro: | 91591 |
|---|---|
| Identificador DC: | https://oa.upm.es/91591/ |
| Identificador OAI: | oai:oa.upm.es:91591 |
| URL Portal Científico: | https://portalcientifico.upm.es/es/ipublic/item/5811041 |