Validation of a new portable metabolic system during an incremental running test

Peinado Lozano, Ana Belen; Martín Caro, Carlos; Pigozzi, Fabio; Calderón Montero, Francisco Javier; Alvarez, María; Maffulli, Nicola; Benito Peinado, Pedro José; Di Salvo, Valter y Díaz Molina, Víctor (2008). Validation of a new portable metabolic system during an incremental running test. "Journal of Sports Science and Medicine", v. 7 (n. 4); pp. 525-531. ISSN 1303-2968.

Descripción

Título: Validation of a new portable metabolic system during an incremental running test
Autor/es:
  • Peinado Lozano, Ana Belen
  • Martín Caro, Carlos
  • Pigozzi, Fabio
  • Calderón Montero, Francisco Javier
  • Alvarez, María
  • Maffulli, Nicola
  • Benito Peinado, Pedro José
  • Di Salvo, Valter
  • Díaz Molina, Víctor
Tipo de Documento: Artículo
Título de Revista/Publicación: Journal of Sports Science and Medicine
Fecha: Diciembre 2008
Volumen: 7
Materias:
Palabras Clave Informales: accuracy,consistency,oxygen consumption,portable metabolic chart,running metabolism ,running ,exercise ,regression analysis,physical fitness
Escuela: Facultad de Ciencias de la Actividad Física y del Deporte (INEF) (UPM)
Departamento: Otro
Licencias Creative Commons: Reconocimiento - Sin obra derivada - No comercial

Texto completo

[img]
Vista Previa
PDF (Document Portable Format) - Se necesita un visor de ficheros PDF, como GSview, Xpdf o Adobe Acrobat Reader
Descargar (312kB) | Vista Previa

Resumen

We tested a new portable metabolic system, the Jaeger Oxycon Mobile (OM) at a range of running speeds. Six subjects carried out, in random order, two incremental tests on a treadmill, one of them using the OM, and the other using the Jaeger Oxycon Pro (OP). There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the OM. Production of CO2 (VCO2) tends to be overestimated by the OM, although the differences are not significant. Ventilation (VE) showed very similar values in both analyzers. Data of VO2 and RER were corrected with a regression equation which minimised the differences among the devices. The portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed systems

Más información

ID de Registro: 2184
Identificador DC: http://oa.upm.es/2184/
Identificador OAI: oai:oa.upm.es:2184
URL Oficial: http://www.jssm.org/b-v7n4.php
Depositado por: Memoria Investigacion
Depositado el: 08 Feb 2010 12:47
Ultima Modificación: 20 Abr 2016 11:56
  • Open Access
  • Open Access
  • Sherpa-Romeo
    Compruebe si la revista anglosajona en la que ha publicado un artículo permite también su publicación en abierto.
  • Dulcinea
    Compruebe si la revista española en la que ha publicado un artículo permite también su publicación en abierto.
  • Recolecta
  • e-ciencia
  • Observatorio I+D+i UPM
  • OpenCourseWare UPM